Sign In | Join Free | My himfr.com
Home > Surge Protective Device Type 3 >

380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module

    Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers
     
    Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers
    • Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers
    • Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers
    • Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers
    • Buy cheap 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module from wholesalers

    380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module

    Ask Lasest Price
    Brand Name : THOR
    Model Number : TRS4-C40
    Certification : CE
    Price : Negotiation
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 20000 pieces/month
    Delivery Time : 3-7 work day
    • Product Details
    • Company Profile

    380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module

    Power lightning protection module, primary power protection, 380V protector 1p40KA.


    Product introduction


    The surge protector is designed according to the standard of IEO and GB. It is applied to power supply protection of equipment system in areas with high lightning risk. It can prevent all kinds of surge currents directly hitting lightning. It can be applied to single-phase and three-phase power supply lines and modular design through different combinations.



    Working principle of product


    During the operation of the equipment, the lightning arrester will play a protective role once the abnormal voltage occurs.
    When the protected device is running under normal working voltage, the arrester will not work, and it will be regarded as a circuit for the ground. Once the high voltage is present and the insulation of the protected equipment is endangered, the lightning arrester acts immediately and leads the high voltage impact current to the earth, thus limiting the amplitude of the voltage and protecting the insulation of the electrical equipment. When the overvoltage is gone, the arrester is restored to its original state quickly, so that the system can supply electricity normally.
    The main function of the lightning arrester is to reduce the voltage value of the protected equipment through the action of parallel discharge gap or nonlinear resistance, and to reduce the voltage value of the protected equipment, so as to protect the power equipment.


    Notice of product


    1. when installing, pay attention to the cable entering and leaving the surge protector. The cables should be separated to avoid the two coupling of surge.


    2. grounding lines should be short, thick and straight, so as to reduce the influence of distributed inductors on the ability of lightning electromagnetic pulse.


    3. lightning arresters are connected in series between protected equipment



    Product features


    1. multi-functional overvoltage protection, lightning and overpressure are no longer afraid of disasters.


    2. limit the precision of the voltage to say how much!


    3. self protection voltage is more than self protection, automatic disconnection and recovery.



    Product specification


    Model and specofocation TRS4-D20TRS4-C40TRS4-B60
    Rated Operating VoltageUn220V/380V
    Max continuous operating voltageUc385V AC
    Voltage protective levelUp(KV)≤1.51.82.0
    Max discharge currentImax(8/20μS)20kA40kA60kA
    Nominal discharge currentIn(8/20μS)10kA20kA30kA
    Response timens〈25
    Ingress Protection Rating
     IP20
    Indication of invalidation Aging invalidation:green Normal,red:Invaldation
    Configuration dimension Three-phase four-wire:72×62×90
    Application Primary protection for in line
    Operating condition Temp:-40℃~+70℃
     RH≤95%(25℃)
     Sea level elevation≤3km
    Remote signal function Can also picking
    Remarks Other max continuous operating voltage can be customized

    Product Installation


    With 35mm standard DIN-rail mounting, connecting copper stranded conductor is 2.5~35mm²

    At front of spd each pole must be setted protection---used fuse or miniature circuit breaker lightning current SPD protection,after SPD breakdown to short circuit protection.

    SPD install on protected line(equipment) to the front and connected to the supply line. A class products install in the building home-entry line hold larger surge current total distribution box. B, C class products most install on the floor distribution box, D class products close to the front-end equipment that smaller surge current, smaller residual voltage place.



    Company profile


    Incorporated in 2006, Zhejiang Thor Electric Co., Ltd has built everything to offer a wide range of innovative and reliable surge protection solutions and products.


    Product packaging:Carton packing


    Transportation method

    1. Express company: FEDEX,UPS,DHL,TNT

    2. Trains, ships, aircraft transport


    Quality 380V 40KA Power Surge Protective Device Type 3 Lightning Protection Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang THOR Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)